Creating and Managing Arrays
4-13
Viewing Drive Status
You can view the status of the drives in an array, including the following information:
!
Drive number—This drive’s sequential position in the controller’s drive list
!
Drive status—Whether the drive is up or down
!
Channel number—Back-end disk bus number
!
Target ID
!
Size—Size of the drive in MB
!
Status—If part of an array, this displays the array name and member number. If
a spare, this displays the type of spare. If unused, displays Available. If drive
was part of an array that no longer exists, displays Leftover.
Note:
If a drive has failed or malfunctioned, it may not be listed.
To view drive status:
1
From the System Menu, select
Array Menu
and press
Enter
.
The Select Array screen displays with a list of existing arrays.
2
Select the array you want and press
Enter
.
The Array Menu screen displays.
3
Select
Drive Status
and press
Enter
.