6 - MAINTENANCE
7. Check that the dust ejector under the filter is operating
correctly.
NOTE:
If, after cleaning, smoke exhaust is abnormal, be
sure to replace the primary element of the air cleaner.
SMIL17CEX0157AA
7
Pre-cleaner (if equipped)
Unlock the pre-cleaner cover,
and remove the
pre-cleaner cup.
Get down from the machine, and
discharge dust and debris accumulated into the cup.
Clean the pre-cleaner cup. Install the pre-cleaner cup,
and lock the pre-cleaner cover.
SMIL18CEX0490AA
8
Pre-cleaner (Auto-discharge type) (if equipped)
Periodically make a visual check of the discharge
opening for being free from any stuck material. If the
machine is operated in dusty environment, the recom-
mended operating practice is to check the discharge
opening once a week.
SMIL17CEX0158AA
9
6-29