Attachment disengagement
To disengage the attachment using CASE
CONSTRUCTION quick coupling system proceed as
follows:
1. Operate the arm and bucket controls so that the arm
is practically vertical, sloping slightly towards the cab,
to release the safety device.
SMIL13CEX2704AB
10
2. Slide the lock device and press the front side of the
quick coupler switch
(1)
to set the unlocking status of
the quick coupling system. The audible alarm device
starts sounding.
3. Extend the bucket cylinder rod completely and main-
tain the hydraulic pressure for approximately
5 – 10 s
so that the latching hook retracts.
SMIL20CEX1397AA
11
4. Operate the bucket and arm controls to lay the attach-
ment safely on flat, level ground.
SMIL13CEX2705AB
12
5. Operate the arm control to unhook the attachment.
6. Press the back side of the quick coupler switch
(1)
to
set the locking status of the quick coupling system.
The audible alarm device stops sounding.
SMIL13CEX2706AB
13
9-14
Summary of Contents for CX130C
Page 16: ...1 GENERAL INFORMATION 1 10...
Page 34: ...2 SAFETY INFORMATION SMIL20CEX1386HA 2 2 18...
Page 75: ...3 CONTROLS AND INSTRUMENTS Display SMIL18CEX0554FB 2 SMIL18CEX0534FB 3 3 29...
Page 112: ...3 CONTROLS AND INSTRUMENTS 3 66...
Page 134: ...4 OPERATING INSTRUCTIONS 4 22...
Page 150: ...5 TRANSPORT OPERATIONS 5 16...
Page 199: ...6 MAINTENANCE Bucket cylinder bottom pin one grease fitting SMIL18CEX0523AA 7 6 49...
Page 231: ...6 MAINTENANCE 8 Check that the tooth is securely fastened CA1C6271 3 6 81...
Page 240: ...6 MAINTENANCE 6 90...
Page 251: ...8 SPECIFICATIONS Working ranges SMIL20CEX1394HA 4 8 9...
Page 254: ...8 SPECIFICATIONS 8 12...
Page 278: ...9 ACCESSORIES 9 24...