6 - MAINTENANCE
Engine coolant
OAT E
XTENDED
L
IFE
C
OOLANT
/A
NTIFREEZE
is the reference genuine product for machine service.
NOTICE:
Never add Supplemental Coolant Additives (SCA) when using
OAT E
XTENDED
L
IFE
C
OOLANT
/A
NTIFREEZE
.
OAT E
XTENDED
L
IFE
C
OOLANT
/A
NTIFREEZE
has to be used if refilling of the cooling system is needed. Refer to the
dedicated procedure and recommendations described in Chapter 6.
OAT E
XTENDED
L
IFE
C
OOLANT
/A
NTIFREEZE
shall be used for the replacement of engine coolant according to the main-
tenance program of the machine. The replacement shall also be tackled in case of repair or replacement of compo-
nents of the cooling system. Refer to the dedicated procedure described in Chapter 6.
The engine cooling system shall always be refilled with coolant solution made by mixture of antifreeze and distilled
(deionized) water.
NOTICE:
Never refill the cooling system with only antifreeze. Never refill the cooling system with only water.
Using
OAT E
XTENDED
L
IFE
C
OOLANT
/A
NTIFREEZE
, a 50/50 mixture of antifreeze and distilled (deionized) water grants
proper performance of the engine cooling system in the above mentioned operating temperature range of the ma-
chine.
OAT E
XTENDED
L
IFE
C
OOLANT
/A
NTIFREEZE
is available as:
• 50/50 PREMIXED coolant solution ready for usage.
• CONCENTRATE antifreeze to be mixed 50/50 with distilled (deionized) water.
NOTICE:
If operating in extreme winter climate, a coolant solution made by 60/40 antifreeze/distilled (deionized) water
mixture shall be used in order to grant proper performance of the engine cooling system.
NOTICE:
Never use coolant solution with more than
60%
of antifreeze. This affects the cooling capacity of the mixture.
When the coolant solution is prepared starting from the CONCENTRATE product, the antifreeze concentration in the
mixture of antifreeze and distilled (deionized) water can be determined with a refractometer designed to measure
ethylene glycol content.
If distilled (deionized) water is not available, use water for dilution with the following properties:
Property
Maximum limit
Total Solids
340 ppm
Total Hardness
170 ppm
Chloride (Cl)
40 ppm
Sulfate (SO4)
100 ppm
Acidity pH
5.5 to 9.0
NOTICE:
Never use hard water, sea water and softened sea water that has been conditioned with salt. The minerals
and salts present in potable water can cause corrosion and deposits resulting in shortened engine life.
6-5
Summary of Contents for CX130C
Page 16: ...1 GENERAL INFORMATION 1 10...
Page 34: ...2 SAFETY INFORMATION SMIL20CEX1386HA 2 2 18...
Page 75: ...3 CONTROLS AND INSTRUMENTS Display SMIL18CEX0554FB 2 SMIL18CEX0534FB 3 3 29...
Page 112: ...3 CONTROLS AND INSTRUMENTS 3 66...
Page 134: ...4 OPERATING INSTRUCTIONS 4 22...
Page 150: ...5 TRANSPORT OPERATIONS 5 16...
Page 199: ...6 MAINTENANCE Bucket cylinder bottom pin one grease fitting SMIL18CEX0523AA 7 6 49...
Page 231: ...6 MAINTENANCE 8 Check that the tooth is securely fastened CA1C6271 3 6 81...
Page 240: ...6 MAINTENANCE 6 90...
Page 251: ...8 SPECIFICATIONS Working ranges SMIL20CEX1394HA 4 8 9...
Page 254: ...8 SPECIFICATIONS 8 12...
Page 278: ...9 ACCESSORIES 9 24...