9 - ACCESSORIES
Setting ranges for auxiliary high-flow hydraulic circuit
The maximum flow rate of the auxiliary high-flow hydraulic circuit can be set by monitor. The setting ranges are related
to the circuit type installed on the machine.
If single-acting circuit is installed, the maximum flow rate can be selected within the steps in the left column of the
table below.
If multifunction circuit is installed, the setting ranges are related to the circuit mode. In the Single-acting mode, the
maximum flow rate can be selected within the steps in the left column of the table below. In the Double-acting mode,
the maximum flow rate can be selected within the steps either in the left column or in the right column of the table
below.
NOTE:
all the values for maximum flow rate are related to the SP work mode. If the auxiliary high-flow hydraulic circuit
is used with a different work mode the actual flow will be lower.
1 pump flow
2 pumps flow
35 L/min
(
9.25 US gpm
)
164 L/min
(
43.32 US gpm
)
39 L/min
(
10.30 US gpm
)
168 L/min
(
44.38 US gpm
)
53 L/min
(
14.00 US gpm
)
182 L/min
(
48.08 US gpm
)
64 L/min
(
16.91 US gpm
)
193 L/min
(
50.99 US gpm
)
75 L/min
(
19.81 US gpm
)
204 L/min
(
53.89 US gpm
)
87 L/min
(
22.98 US gpm
)
216 L/min
(
57.06 US gpm
)
100 L/min
(
26.42 US gpm
)
229 L/min
(
60.50 US gpm
)
111 L/min
(
29.32 US gpm
)
240 L/min
(
63.40 US gpm
)
119 L/min
(
31.44 US gpm
)
248 L/min
(
65.51 US gpm
)
129 L/min
(
34.08 US gpm
)
258 L/min
(
68.16 US gpm
)
NOTE:
Five flow rate values can be set and stored for usage of single-acting hydraulic attachments. Five flow rate
values can be set and stored for usage of double-acting hydraulic attachments.
For the Single-acting circuit the working pressure shall be set manually by the port relief valve on the relevant section
of the control valve.
For the Multi-function circuit the working pressure shall be set manually by the relief valve located behind the boom
foot.
9-7
Summary of Contents for CX130C
Page 16: ...1 GENERAL INFORMATION 1 10...
Page 34: ...2 SAFETY INFORMATION SMIL20CEX1386HA 2 2 18...
Page 75: ...3 CONTROLS AND INSTRUMENTS Display SMIL18CEX0554FB 2 SMIL18CEX0534FB 3 3 29...
Page 112: ...3 CONTROLS AND INSTRUMENTS 3 66...
Page 134: ...4 OPERATING INSTRUCTIONS 4 22...
Page 150: ...5 TRANSPORT OPERATIONS 5 16...
Page 199: ...6 MAINTENANCE Bucket cylinder bottom pin one grease fitting SMIL18CEX0523AA 7 6 49...
Page 231: ...6 MAINTENANCE 8 Check that the tooth is securely fastened CA1C6271 3 6 81...
Page 240: ...6 MAINTENANCE 6 90...
Page 251: ...8 SPECIFICATIONS Working ranges SMIL20CEX1394HA 4 8 9...
Page 254: ...8 SPECIFICATIONS 8 12...
Page 278: ...9 ACCESSORIES 9 24...