7 - TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
SOLUTION
Insufficient warming-up
Perform warming-up
Too much engine oil
Adjust to the appropriate oil amount
Failure of the engine control system
Failure of the supply pump
Failure of the fuel system
Consult your CASE CONSTRUCTION
Dealer
The exhaust smoke is white.
Continuous idling for a long period
(more than two hours)
Raise the engine speed and confirm
that white smoke is not emitted
Failure of the engine control system
Failure of the supply pump
Consult your CASE CONSTRUCTION
Dealer
Clogging of the air cleaner
Clean or replace the element
Failure of the fuel system
Clogging of the exhaust system
The exhaust smoke is black.
Diesel Particulate Diffuser is faulty
Consult your CASE CONSTRUCTION
Dealer
No coolant
Refill
Front of the radiator is clogged with
filth
Perform cleaning
Reserve tank cap not fully tightened
Tighten it securely or replace the cap
with a new one
Coolant is dirty
Clean inside the radiator and replace
the coolant
Failure of the fan clutch
Consult your CASE CONSTRUCTION
Dealer
Reserve tank cap dirty or faulty
Clean or replace the reserve tank cap
Overheat occurs.
Excessive engine oil
Keep the oil at appropriate level
Inappropriate engine oil viscosity
Replace it with oil with appropriate
viscosity
Amount of engine oil is insufficient
Refill
Failure inside the engine
Failure of meters, lights or switches
Oil pressure does not increase.
Oil leakage from the oil filter hose
Consult your CASE CONSTRUCTION
Dealer
Clogging of the air cleaner
Clean the element
Clogging of the fuel filter
Remove moisture and replace the
element
Clogging of the pre-fuel filter
Clean the element
Failure of the engine control system
Consult your CASE CONSTRUCTION
Dealer
Clogging of the supply pump strainer
Clean the strainer
Failure of the engine
Engine does not have enough power.
Diesel Particulate Diffuser is faulty
Consult your CASE CONSTRUCTION
Dealer
7-2
Summary of Contents for CX130C
Page 16: ...1 GENERAL INFORMATION 1 10...
Page 34: ...2 SAFETY INFORMATION SMIL20CEX1386HA 2 2 18...
Page 75: ...3 CONTROLS AND INSTRUMENTS Display SMIL18CEX0554FB 2 SMIL18CEX0534FB 3 3 29...
Page 112: ...3 CONTROLS AND INSTRUMENTS 3 66...
Page 134: ...4 OPERATING INSTRUCTIONS 4 22...
Page 150: ...5 TRANSPORT OPERATIONS 5 16...
Page 199: ...6 MAINTENANCE Bucket cylinder bottom pin one grease fitting SMIL18CEX0523AA 7 6 49...
Page 231: ...6 MAINTENANCE 8 Check that the tooth is securely fastened CA1C6271 3 6 81...
Page 240: ...6 MAINTENANCE 6 90...
Page 251: ...8 SPECIFICATIONS Working ranges SMIL20CEX1394HA 4 8 9...
Page 254: ...8 SPECIFICATIONS 8 12...
Page 278: ...9 ACCESSORIES 9 24...