5–25
62-11640
PROTECT DATA WITH PIN
YES /
NO
NOTE
Master technician PIN code is described
in
. Using TRU
−
Tech, a data
protect PIN code, which can override the
master technician PIN code, may be
entered into the control system.
YES = The data protect PIN code will override the
master technician PIN code and data protect code
must be entered to use the USB Interface port or
data recorder print functions.
NO = The data protect PIN code will not override the
master technician PIN code when using the USB In-
terface port or data recorder print functions.
PARAMETERS LOCKOUT
YES /
NO
YES
=
All
Functional
Parameters
are
locked
and
cannot be changed using the display mounted keys.
NO = Functional Parameters can be changed using
the display mounted keys, unless individually locked
out by TRU-Tech.
8 HR ADDITIONAL DATA
YES
/ NO
YES = When START/RUN
−
OFF switch is placed in
the OFF position, the DataLink data recorder will
continue to record data for an additional 8 hours.
NO = When START/RUN
−
OFF switch is placed in
OFF, DataLink data recorder will stop recording.
SATELLITE COMM
(This Configuration is an option, it
will not display if the option is not
installed.)
OTHER
QUALCOMM
OTHER = The microprocessor is set for communica-
tion from Qualcomm T2 (Trailer Tracs 2) or any other
supplier.
QUALCOMM =- The microprocessor is set for com-
munication from Qualcomm Trailer Tracs.
HIGH SPEED DELAY
1 Minute
0 to 10 minutes in 0.5
minute increments
Select the length of time unit remains in low speed
before transitioning to high speed.
LIGHT BAR
NOT INSTALLED
2 LIGHT
NOT INSTALLED = a remote light bar is not installed
2 light = a two light bar is installed.
NATURAL DEFROST
YES /
NO
YES = Natural defrost will be allowed
NO = Natural defrost will not be allowed Refer to
for more information on natural defrost)
BATT CHARGER
(Applicable to unit - not lift gate -
battery charger only.)
NO TEMP
SENSOR
WITH TEMP
SENSOR
NO TEMP SENSOR = Use this setting when the bat-
tery charger does not have the temperature sensor
wire.
WITH TEMP SENSOR = Use this setting when the
battery charger does have the temperature sensor
wire (connected to the battery positive post).
SET DATE AND TIME
Indicates to the main microprocessor the current date and time. Refer to
for instructions on entering the date and time.
NOTE
Date and Time may also be configured under “Unit Identification”.
Table 5–1 Configuration Settings
(Refer to
Section 5.2.3
for instructions on entering Configuration settings)
Configuration
Selections
Description
Summary of Contents for Vector 8500
Page 23: ...62 11640 1 6 1 3 SAFETY DECALS ...
Page 24: ...1 7 62 11640 62 03958 ...
Page 25: ...62 11640 1 8 ...
Page 26: ...1 9 62 11640 ...
Page 27: ...62 11640 1 10 ...
Page 125: ...62 11640 SECTION 6 MESSAGECENTER PARAGRAPH NUMBER Page 6 1 MESSAGECENTER MESSAGES 6 1 ...
Page 321: ......
Page 322: ......