6–3
62-11640
PRESTRIP STOPPED BY USER
Pretrip has been stopped by user.
PRODUCTSHIELD: ECONO ON
The unit is operating in ProductShield Econo which overrides normal
unit Start
−
Stop or Continuous Run operation. Refer to
PRODUCTSHIELD: HIGH AIR ON
The unit is operating in ProductShield High Air which overrides normal
unit speed operation. Refer to
PRODUCTSHIELD: WINTER ON
The unit is operating in ProductShield Winter which overrides normal
unit operation. Refer to
RECORDING DATA
−
PLEASE WAIT
MICRO WILL RESTART WHEN
COMPLETE
This message will be displayed when the unit is starting and the
main microprocessor is completing communicating with another
module.
RECOVER / LEAK CHK / EVAC MODE
This message will be displayed when the unit is in Service Mode
and the system is ready for recovery and leak testing.
REMOTE SWITCH 1 OPEN
Remote switch is open. May be connected to a refrigerated
compartment door or a remote control switch.
REMOTE SWITCH 1 OPEN
−
LOW
SPEED
Shows that the remote switch is open and that the unit is running in
low speed. Switch may be connected to a refrigerated compartment
door or a remote control switch.
SERVICE MODE
Selection which is used when servicing the refrigeration system.
Refer to
SETPOINT CHANGED
The new setpoint has been entered (saved into microprocessor
memory), the new setpoint will be used.
SETPOINT NOT CHANGED
The new setpoint has NOT been entered (NOT saved into micropro-
cessor memory), the old setpoint will be used.
SETTING SMV: XXX %
The START/RUN
−
OFF switch has been toggled out of the OFF
position and the CSMV is opening.
SLEEP MODE, OFF / ON TO WAKE
The unit is cycled off in Sleep Mode. Place the START/RUN
−
OFF
switch in the OFF position, then back to the START/RUN position
to wake the microprocessor up.
SLEEP WARNING: DOOR OPEN
The unit is configured for Rail Mode and the unit is in Sleep Mode
and a refrigerated compartment door is open. The unit will start as
needed for Sleep Mode.
SLEEP WARNING: NO TEMP CONTROL The unit is running in Sleep Mode to charge the battery and (in
Engine Operation) warm the engine coolant. It is not running to
provide temperature control.
SLEEP WARNING: REMS1(2) OPEN
The unit is configured for Rail Mode and the unit is in Sleep Mode
and a remote switch is open. The switch may be connected to a
refrigerated compartment door or to a remote control switch. The
unit will start as needed for Sleep Mode.
SMV CLOSING: WAIT XXX SECONDS
Power Up and the CSMV is closing. XX indicates the number of
seconds remaining until valve is fully closed.
START STOP LOCKED
The setpoint has been locked into Start
−
Stop Operation. Continuous
Run can not be selected.
START
−
STOP MODE SELECTED
Start
−
Stop Operation has been selected.
STATUS OK
The unit is operating correctly.
Table 6–1 MessageCenter Messages
Message
Description
Summary of Contents for Vector 8500
Page 23: ...62 11640 1 6 1 3 SAFETY DECALS ...
Page 24: ...1 7 62 11640 62 03958 ...
Page 25: ...62 11640 1 8 ...
Page 26: ...1 9 62 11640 ...
Page 27: ...62 11640 1 10 ...
Page 125: ...62 11640 SECTION 6 MESSAGECENTER PARAGRAPH NUMBER Page 6 1 MESSAGECENTER MESSAGES 6 1 ...
Page 321: ......
Page 322: ......