62-11640
9–2
Indication/Trouble
Possible Causes
Action / Reference
9.1.2
Engine Starts Then Stops
Engine stops after several rota-
tions
Fuel supply restricted
Check
No fuel in tank
Check
Leak in fuel system
Check
Faulty fuel control operation
Engine Manual
Plugged fuel filter
Plugged inlet screen to mechanical pump
Plugged inlet screen to electric pump
Injector nozzle(s) defective
Engine Manual
Injection pump defective
Engine Manual
Air cleaner or hose restricted
Safety device open
ENCU defective
Replace
Electric fuel pump malfunction
Mechanical fuel pump malfunction
Engine Manual
Oil pressure switch defective
Replace
9.1.3
Engine Will Not Shut Off
Engine will not shut off
ENCU operation defective
Replace
9.1.4
Starter Motor Malfunction
Starter motor will not crank or
turns slowly
Battery insufficiently charged
Battery cable connections loose or corroded
Check
Battery cables defective
Replace
Excessively worn, open or defective starter brushes
Engine Manual
Starter motor solenoid defective or damaged
Engine Manual
Incorrect grade of lubricating oil
Internal generator damage
Generator magnetically locked, casing drag
Starter motor turns but pinion
does not engage
Pinion or ring gear obstructed or worn
Clean both,
remove burrs,
or replace
Starter motor does not disengage
after engine starts
Starter motor solenoid defective
Engine Manual
Defective starter
Engine Manual
9.1.5
Malfunction in the Engine Starting Circuit
No power to starter solenoid (SS)
Battery condition
Load Test
Damaged or corroded electrical connections at starter
Check/Repair
ENCU defective
Replace
No power from 3MM-12 to Starter Solenoid connector
Check/Repair
Summary of Contents for Vector 8500
Page 23: ...62 11640 1 6 1 3 SAFETY DECALS ...
Page 24: ...1 7 62 11640 62 03958 ...
Page 25: ...62 11640 1 8 ...
Page 26: ...1 9 62 11640 ...
Page 27: ...62 11640 1 10 ...
Page 125: ...62 11640 SECTION 6 MESSAGECENTER PARAGRAPH NUMBER Page 6 1 MESSAGECENTER MESSAGES 6 1 ...
Page 321: ......
Page 322: ......