62-11640
7–90
05005
BAD F9 FUSE
• ACTIVATION: CCB Fuse Alarm; Feedback from CCB indicates fuse is missing or blown. Signal must be
present for at least 3 seconds.
• UNIT CONTROL: Engine and Electric Operation: Alarm only.
• RESET CONDITION: Replace or fix fuse issue.
NOTE: Follow the steps below until a problem is found. Once a repair or correction has been made, clear the
alarm(s). (Refer to Note 1 in
Section, page 7-2.) Operate the unit through the appropriate modes to see if
any active alarm occurs. Continue with the steps below as necessary.
CORRECTIVE ACTIONS:
1.
Check Fuse F9
a. Visually check fuse Verify correct fuse, check fuse holder for damage, see
. Replace
fuse as required. Clear alarms, restart and check for repeat alarm(s).
b. Check voltage. Check voltage through the fuse, if fuse is blown, replace it.
c. Check wiring. Verify there is no physical damage to harness, and no damage, moisture, or corro-
sion in connectors.
05006
POWER ENABLE RELAY FUSE ALARM
• ACTIVATION: Fuses 9 and 10 must be in a failed state in order to trigger the Power Enable Relay (PER)
Fuse Alarm.
• UNIT CONTROL: Alarm only.
• RESET CONDITION: Fuses are not in a failed state.
NOTE: Follow the steps below until a problem is found. Once a repair or correction has been made, clear the
alarm(s). (Refer to Note 1 in
Section, page 7-2.) Operate the unit through the appropriate modes to see if
any active alarm occurs. Continue with the steps below as necessary.
CORRECTIVE ACTIONS:
1.
Check Fuse F5
a. Visually check fuse. Verify correct fuse, and check fuse holder for damage, see
Replace fuse as required. Clear alarms, restart and check for repeat alarm(s).
b. Check voltage. Check voltage through the fuse, if fuse is blown, replace it.
c. Check wiring. Verify there is no physical damage to harness, and no damage, moisture, or corro-
sion in connectors.
2.
Check Fuse F9 and F10
a. Visually check fuses. Verify correct fuse, and check fuse holder for damage, see
.
Replace fuse as required. Clear alarms, restart and check for repeat alarm(s).
b. Check voltage. Check voltage through the fuse, if fuse is blown, replace it.
c. Check wiring. Verify there is no physical damage to harness, and no damage, moisture, or corro-
sion in connectors.
Summary of Contents for Vector 8500
Page 23: ...62 11640 1 6 1 3 SAFETY DECALS ...
Page 24: ...1 7 62 11640 62 03958 ...
Page 25: ...62 11640 1 8 ...
Page 26: ...1 9 62 11640 ...
Page 27: ...62 11640 1 10 ...
Page 125: ...62 11640 SECTION 6 MESSAGECENTER PARAGRAPH NUMBER Page 6 1 MESSAGECENTER MESSAGES 6 1 ...
Page 321: ......
Page 322: ......