311 Working error in external input/output
service [err]
S
312 Working error in timer service [err]
S
320 PAN/TILT operation error [err]
S
330 Failure of fan [err]
S
331 Failure of heater [err]
S
410 Event service initialization error [crit]
S
411 External input/output service
initialization error [crit]
S
412 Timer service initialization error [crit]
Description
cannot work extio [%1][%2][%3]
(S311)
%1
Error number
%2
Cause of error
%3
Error information
Meaning
An error occurred while the external
input/output device service was
running.
Countermeasure
If the problem persists after rebooting,
the camera is faulty. Arrange for
servicing.
Description
cannot work timer [%1][%2][%3]
(S312)
%1
Error number
%2
Cause of error
%3
Error information
Meaning
An internal error occurred in the timer
service.
Countermeasure
If the problem persists after rebooting,
the camera is faulty. Arrange for
servicing.
Description
%1 error occurred. [%2] (S320)
%1
PAN | TILT
%2
Warning details
Meaning
An error occurred during operation or
stopping of PAN/TILT.
Countermeasure
Check that the camera is not touching
the dome, etc.
If the error is not caused by problems
such as contact with peripheral items,
the camera is faulty. Arrange for
servicing.
Description
FAN [%1] failure (S330)
%1
Fan number
Meaning
Detected that the fan is not rotating or
the rotation speed has significantly
decreased.
Countermeasure
If the problem persists after rebooting,
the fan may have failed. Arrange for
servicing.
Description
HEATER [%1] failure (S331)
%1
Heater number
Meaning
An abnormality was detected when
using the heater.
Countermeasure
There may be a connection problem
with the heater unit you attached, so
check the connections (VB-M641VE).
If the problem persists after rebooting,
the heater may have failed. Arrange for
servicing.
Description
event initialization error [%1][%2]
(S410)
%1
Error number
%2
Cause of error
Meaning
An error occurred in the initialization of
the event service.
Countermeasure
If the problem persists after rebooting,
the camera is faulty. Arrange for
servicing.
Description
extio initialization error [%1][%2]
(S411)
%1
Error number
%2
Cause of error
Meaning
An error occurred in the initialization of
the external input/output device
service.
Countermeasure
If the problem persists after rebooting,
the camera is faulty. Arrange for
servicing.
Description
timer initialization error [%1][%2]
(S412)
%1
Error number
%2
Cause of error
Meaning
An error occurred in the initialization of
the timer service.
Countermeasure
If the problem persists after rebooting,
the camera is faulty. Arrange for