User Set Control
The VT Camera Link cameras provide three non-volatile spaces (Flash) for storing parameter settings and one
work space (RAM) for operating the camera. Non-volatile spaces are divided into a Factory space (Factory
Setting) that contains default setting values entered during the manufacturing, and two User spaces (User 1
Setting and User 2 Setting) that are available for saving user-defined setting values.
You can save the current camera settings to a user space or you can load the settings stored in one of the non-
volatile spaces into the camera’s work space. The default setting values stored in the factory space can be
loaded into the camera’s work space, but cannot be changed.
The setting values in the camera
’s volatile memory will be lost if the camera is reset or powered off.
To use the current setting values in the work space after a reset, you must save the settings to one of the user
spaces.
By default, the Factory Setting will be loaded into the camera when the camera is reset or powered on. You can
change the Configuration Initialization value to select which setting values will be loaded when the camera is
reset or powered on.
Figure 10.1 User Set Control