VT Camera Link series
Page 63 of 88
VW40-161-001
Command Syntax
Return Value
Description
Set Analog Gain
Get Analog Gain
sag 1|2|3|4
gag
OK
1|2|3|4
Sets the Analog Gain.
1/2/3/4: Analog gain (
1,
2,
3,
4)
Set Digital Gain
Get Digital Gain
sdg f
gdg
OK
f
Sets the Digital Gain.
f: Digital gain <Float>
(Setting Range: 1.000 ~ 8.000)
Set Black Level
Get Black Level
sdbl n
gdbl
OK
n
Sets the Black Level.
n: Black level (Setting Range: -255 ~ 255)
Generate DSNU Data All gdda
OK
Generates and saves the DSNU data for each
Analog Gain setting values.
Generate DSNU Data
gdd
OK
Generates the DSNU data for the current
Analog Gain setting value.
Save DSNU Data
sdd
OK
Saves the generated DSNU data in the non-
volatile memory.
Load DSNU Data
ldd
OK
Loads the DSNU data from the non-volatile
memory into the volatile memory.
Set DSNU Transform
sdt n1 (n2) v1 OK
Performs additional correction to the PRNU
correction values.
n1: X coordinate of a start pixel
n2: X coordinate of an end pixel
v1: Black level value to be added to the
specified region (-255 ~ 255)
Set DSNU Coefficient
Get DSNU Coefficient
sdc n f1
gdc n1 (n2)
OK
f1
Sets or retrieves the DSNU Correction
Coefficient.
n: X coordinate of a pixel to set
n1: X coordinate of a start pixel
n2: X coordinate of an end pixel
f1: DSNU correction coefficient
(Black Level = 0.1 ~ 4095)
Table 10.6 Command List #4