VT Camera Link series
Page 59 of 88
VW40-161-001
The commands related to User Set are as follows.
Configurator Parameters Command
Value
Description
Load Setting
lcf 0
Factory Space
Loads the Factory Default Settings to the
camera.
lcf 1
User 1 Space
Loads the User 1 Settings to the camera.
lcf 2
User 2 Space
Loads the User 2 Settings to the camera.
Save Setting
sct 1
User 1 Space
Saves the current settings to the User 1 Setting.
sct 2
User 2 Space
Saves the current settings to the User 2 Setting.
Start-Up
sci 0
Factory Setting Applies the Factory Default Settings when reset.
sci 1
User 1 Setting
Applies the User 1 Settings when reset.
sci 2
User 2 Setting
Applies the User 2 Settings when reset.
Table 10.1 Commands related to User Set Control
10.2.1
Factory Default Setting Values
When you power the VT Camera Link camera for the first time on, the factory default setting values will be
loaded into the camera and the factory default setting values are as follows.
Configurator Parameters
Value
Operation Mode
TDI
Direction
Forward
TDI Stages
Maximum Integration Stages
Trigger Mode
Off
Test Image
None
Binning
1
Data Bit
8
PRNU Correction
On
Tap Mode
8 Tap
Analog Gain
1
Digital Gain
1
Line Rate
35
㎑
Table 10.2 Factory Default Setting Values