VT Camera Link series
Page 64 of 88
VW40-161-001
Command Syntax
Return Value
Description
Set LUT Select
Get LUT Select
sls
0|1
gls
OK
0|1
Sets the LUT feature.
0: Disables the LUT feature.
1: Enables the LUT feature.
Generate PRNU Data
gpd n
OK
Generates the PRNU data.
n: Target level
(Setting Range: 1 ~ 255, 0: Auto)
Set PRNU Mode
Get PRNU Mode
sprnu 0|1
gprnu
OK
0|1
Sets the PRNU Correction feature.
0: Disables the PRNU Correction feature.
1: Enables the PRNU Correction feature.
Save PRNU Data
spd
OK
Saves the PRNU data in the non-volatile
memory.
Load PRNU Data
lpd
OK
Loads the PRNU data from the non-volatile
memory into the volatile memory.
PRNU Selector
spi
0|1|2|3|4
gpi
OK
0|1|2|3|4
Selects a location to save PRNU data to or
load PRNU data from.
0/1/2/3/4: PRNU data storage area
Set PRNU Transform
spt n1 (n2) f1 OK
Performs additional correction to the PRNU
correction values.
n1: X coordinate of a start pixel
n2: X coordinate of an end pixel
f1: Gain value to be multiplied to the specified
region (0.1 ~10.0).
Set PRNU Coefficient
Get PRNU Coefficient
spc n f1
gpc n1 n2
OK
f1
Sets or retrieves the PRNU Correction
Coefficient.
n: X coordinate of a pixel to set
n1: X coordinate of a start pixel
n2: X coordinate of an end pixel
f1: PRNU correction coefficient
(Gain = 0.1 ~10.0)
Set Camera Link mode
Get Camera Link mode
scl
0|1|2|3
gcl
OK
0|1|2|3
Sets the Camera Link Output mode.
0: 2 Tap
1: 4 Tap
2: 8 Tap
3: 10 Tap
Table 10.7 Command List #5