VT Camera Link series
Page 17 of 88
VW40-161-001
Figure 5.4 M42 mount based VT CL Series Mechanical Dimension
5.5.1
Camera Mounting and Heat Dissipation
You must mount the camera on a heat dissipation structure to maintain the temperature of the camera housing
at 50
℃
or less. Given the low power consumption of the VT series camera, its housing temperature during
operation will generally stay within the specified limits. However, overheating can occur if heat dissipation is
restricted or if the camera is mounted on a severe environment. It is recommended to follow the general
guidelines below when you mount the camera.
In all cases, you should monitor the temperature of the camera housing and make sure that the temperature
does not exceed 40
℃
. You can monitor the inter
nal temperature of the camera by using the ‘gct’ command.
If your camera is mounted on a metal component in your system, this may provide sufficient heat
dissipation.