8.1.3
Rescaler Mode
In the
Rescaler Mode
, you can modulate the period of the external trigger signal as desired. For example, if you
supply the external trigger signal into the camera’s I/O receptacle using the conveyor’s encoder, the number of
output pulses per revolution of the encoder is fixed. In this situation, you can modulate the period of the trigger
signal received from the camera in the following manner to match the pitch of the image in vertical direction.
Line Rate (
㎐
) = External Trigger Line Rate
×
Rescale Rate
Figure 8.3 Rescale Rate = 0.5
The commands related to the Rescaler Mode are as follows.
Configurator Parameters
Command
Value
Description
Rescaler Mode
srm 0
Off
Disables Rescaler Mode.
srm 1
On
Enables Rescaler Mode.
Rescale Rate
srr f
0.010000 ~ 100.000000
Set the trigger rescaler rate for
converting trigger signals.
f: Float, 0.010000 ~ 100.000000
Rescaler Filter
srf 0
16
Set the rescaler filter factor to
decrease the jitter of the external
trigger signals.
srf 1
32
srf 2
64
srf 3
128
srf 4
256
srf 5
512
Table 8.1 Commands related to Rescaler Mode