Command Syntax
Return Value
Description
Set Trigger Rescaler Mode
Get Trigger Rescaler Mode
srm 0|1
grm
OK
0|1
Enables the Trigger Rescaler feature.
0: Disables the Trigger Rescaler feature.
1: Enables the Trigger Rescaler feature.
Set Trigger Rescaler Rate
Get Trigger Rescaler Rate
srr
f
grr
OK
f
Sets the trigger rescaler rate.
f: Rescaler rate <Float>
(Setting range: 0.010 ~ 100.000)
Set Trigger Rescaler Filter
Get Trigger Rescaler Filter
srf
0|1|2|3|4|5
grf
OK
0|1|2|3|4|5
Sets the Trigger Rescaler Noise Filter.
0: 16
1: 32
2: 64
3: 128
4: 256
5: 512
Set Operation Mode
Get Operation Mode
som 0|1
gom
OK
0|1
Sets the camera
’s operation mode.
0: TDI mode
1: Area mode
Set Strobe Mode
Get Strobe Mode
ssm 0|1|2|3
gsm
OK
0|1|2|3
Sets whether to output strobe signals.
0: Off
1: Outputs strobe signals according to the
Strobe Duration setting value.
2: Outputs signals of which the width is equal
to the trigger signals applied to the
camera.
3: Outputs continuous High signals.
Set Strobe Inverter
Get Strobe Inverter
ssp 0|1
gsp
OK
0|1
Sets whether to invert strobe signals.
0: Disables the inversion of strobe signals.
1: Enables the inversion of strobe signals.
Set Strobe Delay
Get Strobe Delay
sto
f
gto
OK
f
Sets a delay to the strobe signal.
f: Strobe delay (
㎲
) <Float>
(Setting range: 0.00 ~ 1000.00
㎲
)
Set Strobe Duration
Get Strobe Duration
ssr
f
gsr
OK
f
Sets a width of the strobe signal in
microseconds when the Strobe Mode is set
with the ssm 1 command.
f: Strobe duration (
㎲
) <Float>
(Setting range: 1.00 ~ 1000.00
㎲
)
Table 10.5 Command List #3