VW40-161-001
10 Camera Configuration
10.1
Setting Commands
You can configure all camera settings via RS-644 serial interface of the Camera Link. When you want to control
the camera using a terminal or to access directly to the camera at your application, you need to set your network
as follows.
Baud Rate:
115200 bps
Data Bit:
8 bit
Parity Bit:
No Parity
Stop Bit:
1 stop bit
Flow Control:
None
All camera setting commands are transmitted in the ASCII command type except a command for transmitting a
large file such as firmware download. All camera setting commands are transmitted from the user application
and then the camera returns a response (“OK”, “Error” or information) for a command. When you execute a write
command, the camera returns a response to inform whether the command has been successfully executed.
When you execute a read command, the camera returns an error or information.
Command Format:
<command> <parameter1> <parameter2> <cr>
0 – 2 parameters follow the command.
Response:
If a write command is successfully executed
OK <cr> <lf>
ex) Write Command
In response to a “set 100” command the camera will return (in hex value)
Command:
73 65 74 20 31 30 30 0D
set 100<cr>
Response:
73 65 74 20 31 30 30 0D 0A
4F 4B 0D 0A
3E
set 100<cr><lf>
OK<cr><lf>
>
Echo
result
prompt