VT Camera Link series
Page 57 of 88
VW40-161-001
If a read command is successfully executed
<parameter1> <cr> <lf>
ex) Read Command
In response to a “get” command the camera will return (in hex value)
Command:
67 65 74 0D
get <cr>
Response:
67 65 74 0D 0A
31 30 30 0D 0A
3E
get<cr><lf>
100<cr><lf>
>
Echo
response
prompt
If a command is not executed successfully
Error: <Error Code> <cr> <lf>
Prompt:
A prompt always follows after the response. ‘>’ is used as prompt.
Types of Error Code
0x80000481: value of parameter is not valid
0x80000482: the number of parameter is not matched
0x80000484: command does not exist
0x80000486: no permission to execute