VT Camera Link series
Page 87 of 88
VW40-161-001
C.2 Adjusting and Saving Additional PRNU Correction Value
For example, if you want to apply
1.1 gain from the 100
th
pixel to the 109
th
pixel, follow the procedures below.
1.
Click
Tool
>
Terminal
in the Configurator.
2.
Input the
spt 100 109 1.1
command into the Terminal input box.
3.
Specify a location to save by using the
spi 0/1/2/3/4
command and execute the
spd
command to save the
additional
PRNU correction value in the camera’s Flash (non-volatile) memory. The existing values in the
Flash memory will be overwritten. To ignore the adjusted PRNU correction values and load the existing
values in the Flash memory, specify a location to load from by using the
spi 0/1/2/3/4
command and
execute the
lpd
command.
Figure B.2 Additional PRNU Correction
Before executing the
spt
command, if you set the
PRNU Mode
to
On
by using the
sprnu
command, you can determine the adjusted PRNU correction values in the acquired line images.