AFX SERIES® OPERATION MANUAL
SECTION 5: UNPACKING AND INSTALLATION
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS)
• All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 93 of 402
Call Out
LABEL
Description
6
OUTPUT, ABCNNN
Power Output Connector for Transformer chassis.
Connect the load using this output connector using
the Phase and Neutral positions shown. Note that
all three neutral connections are shorted together
internally.
7
INPUT
AC input connection. Use a standard IEC modular
line cord to connect to local 115V or 230V utility
voltage. Without this power connection, the
transformer chassis is inoperative and in bypass
mode. The AC on/off switch is located on the front
panel of the of transformer chassis.
Table 5-7: Transformer Option Chassis, Rear Panel Connectors