Query Syntax
[SOURce:]IMPEDance[:R][:LIMit]:MINimum?
Description
This command return the minimum allowable setting value for the R
component of the output impedance.
Parameters
None
Parameter Format
N/A
Query Example
IMPED:R:MIN?
-1.000
Command Syntax
[SOURce:]IMPEDance:L
Description
This command sets the L value for the output impedance. Available
programming range is -
0.00000000
~
0.00005000
(Henry).
Parameters
<L>
Parameter Format
<nr2>
Example
IMPED:L 0.00002
Query Format
[SOURce:]IMPEDance:L?
Returned Data Format
<nr2>
Query Example
IMPED:L?
0.00002
Query Syntax
[SOURce:]IMPEDance:L[:LIMit]:MAXimum?
Description
This command return the maximum allowable setting value for the L
component of the output impedance.
Parameters
None
Parameter Format
N/A
Query Example
IMPED:L:MAX?
0.00005000
Query Syntax
[SOURce:]IMPEDance:L[:LIMit]:MINimum?
Description
This command return the minimum allowable setting value for the L
component of the output impedance.
Parameters
None
Parameter Format
N/A
Query Example
IMPED:L:MIN?
0.00000000