Error Source
Code
Category
Error Message
Possible Cause
Resolution
Front panel
Fault
330
Error
Global fault detected.
Possible un-energized
unit or node.
An inconsistency was
detected in the power
source's internal
communication network.
Turn unit off, check
parallel cable connections
if present and then turn
unit back on. If problem
recurs, contact customer
service.
Front panel
Fault
331
Error
Unit discovery fault. Run
unit discovery to recover.
Error during discovery.
Discovery of parallel units
failed
Check all parallel cables
between units. Run
parallel unit discovery
from System menu to
recover
Front panel
Fault
332
Error
Undiscovered unit/node
detected. Run unit
discovery to recover.
An inconsistency was
detected in the power
source's internal
communication network.
Turn unit off, check
parallel cable connections
if present and then turn
unit back on. If problem
recurs, contact customer
service.
Front panel
Fault
333
Error
Node in non-operational
mode. Run unit discovery
to recover.
An inconsistency was
detected in the power
source's internal
communication network.
Turn unit off, check
parallel cable connections
if present and then turn
unit back on. If problem
recurs, contact customer
service.
Front panel
Fault
334
Error
Power failure.
Check AC input voltage. If
error persists, contact
customer service
Front panel
Fault
335
Error
Remote inhibit was issued
from remote interface.
Setting conflict. Remote
inhibit conflicts with
Output state
Check Remote inhibit
mode setting and
connections
Front panel
Fault
336
Error
System about to reboot.
Notification. Reboot
imminent. Normal after
completing front panel
firmware update
Wait for all firmware
updates to be completed
Front panel
Fault
337
Error
Missed node.
An inconsistency was
detected in the power
source's internal
communication network.
Try recycling power. If
error persists, contact
customer service
Front panel
Fault
338
Error
One or more inverters did
not get enabled.
Failed to enable one or
more output power
stages
Try recycling power. If
error persists, contact
customer service
Front panel
Fault
339
Error
One or more primaries
did not get enabled.
Failed to enable one or
more input power stages
Try recycling power. If
error persists, contact
customer service
Front panel
Fault
340
Error
Firmware version
mismatch
Firmware Error. Power
stage firmware version is
older than expected
Check for correct
firmware image file and
version.
Front panel
Fault
341
Error
Firmware version
mismatch. Front panel
version is older than
Firmware Error. Front
panel firmware version is
older than expected
Check for correct
firmware image file and
version.