Other Measurements
Measurements
Waveform Capture
Time Domain
1024 samples/period
Parameters
V
LN
-A, V
LN
-B, V
LN
-C, IA, IB, IC
Samples/cycle
1024 (512 in UPC Compatibility mode)
Record Length
1 Period of fundamental Frequency
Bandwidth
27.45 kHz
Harmonics Measurements
Amplitude Range
H1 ~ H50
Accuracy
Amplitude ± 1.0 %
Phase Range
0 ~ 359.9
Accuracy
< 20
sec
Bandwidth
27.45 kHz
Display Modes
Table format, Graph Format
4.8
Transients
Transients
Programming
No. of Entries
200 Steps, 400 Segments
Parameters
Voltage, Frequency, Phase B &C, Ramp Time, Dwell Time
Dwell Time Range
0.0002 – 99999 sec
Ramp Time Range
0.0002 – 10 sec
Time Resolution
0.2 msec
Edit Modes
Add at End, Insert Before, Delete
Execution
Run Control
Run from Step # to Step #
Run, Step, Restart, Stop
Program Storage
Non-Volatile
100, Pr Transients