Error Source
Code
Category
Error Message
Possible Cause
Resolution
Front panel
Error
-282
Remote
Execution error: Invalid
program name.
Invalid program name
passed. Special characters
are not allowed in
program names
Use names containing
letters and numbers only
Front panel
Error
-281
Remote
Execution error: Cannot
create program.
Request to create new
program rejected.
Program data sent is not
correct
Check program content
Front panel
Error
-256
Remote
Execution error: File not
found.
File specified does not
exist
Check for correct file
name
Front panel
Error
-253
Remote
Execution error: Media is
corrupted.
Media used has been
corrupted
Reformat or replace
media
Front panel
Error
-240
Remote
Execution error:
Hardware error.
Unspecified Hardware
Error detected. Cause
unknown
Try recycling power. If
error persists, contact
customer service
Front panel
Error
-224
Remote
Execution error: Illegal
parameter value.
Invalid parameter value
Check value
Front panel
Error
-222
Remote
Execution error:
Argument out of range.
Argument passed exceeds
allowable range
Adjust parameter to be
within valid range
Front panel
Error
-221
Remote
Execution error: Conflict
in configuration setting.
Configuration setting
conflict
Check configuration
settings
Front panel
Error
-203
Remote
Execution error:
Permission denied.
Read or Write access to
memory selected denied.
Some memory areas are
off limits
Check memory type or
permissions
Front panel
Error
-158
Remote
Command error: String
data is not allowed.
Passing string data when
string type is not
supported
Pass correct data type
Front panel
Error
-138
Remote
Command error: Numeric
suffix is invalid.
Number suffix not valid
Check value
Front panel
Error
-131
Remote
Command error: Numeric
suffix is out of range.
Suffix number passed
exceeds allowable range
Adjust suffix to be within
valid range
Front panel
Error
-113
Remote
Command error:
Undefined header.
Command Header not
defined
Check command
Front panel
Error
-109
Remote
Command error: Invalid
number of parameters.
Invalid number of
parameters. Too few or
too many parameters are
being passed
Check for correct no. of
parameters
Front panel
Error
-108
Remote
Command error:
Parameters error.
Errors in parameters
Check parameter values
Front panel
Error
-103
Remote
Command error: Invalid
separator.
Separator used is invalid
Use correct separator
character
Front panel
Error
-102
Remote
Command error: Syntax
error.
Syntax Error
Check syntax
Front panel
Error
53
Error
Error during firmware
update.
Firmware Update Error.
Update may have failed
Check for correct
firmware image file and
version.
Front panel
Error
54
Error
Calibration coefficient
cannot be negative.
Negative Calibration
Coefficients are not
allowed
Make sure cal coefficients