AFX SERIES® OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS)
• All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 220 of 402
Command Syntax
PROGram:EXECuted:DEFine <cr>
Description
This command programs all values stored in the selected program
number. Both steady-state and transient segment parameter names
and values may be sent. Program parameters are defined in the
following sections.
NOTE: Only commas may separate the values, NO Carriage Returns or
Line Feeds may separate the values within a single command
message.
Parameters
Refer to PROGram:SELected:DEFine command
Parameter Format
<cr>,<cr>,….,<cr>,<cr>
Example
Query Format
PROGram:EXECuted:DEFine?
Returned Data Format
<cr>,<cr>,….,<cr>,<cr>
Query Example
PROG:EXEC:DEF?
-> parameter list
Query Format
PROGram[:SELected]:DEFine:ALL?
Description
This query returns the parameter list for the selected program
number or name.
Parameters
Option: PROGRAM, NUMBER [,<cr>} or [,<nr1>]
Option: MEMORY [,<cr>]– Available are: INTERNAL | RAM | USB
Parameter list define string <cr>,<cr>,….,<cr>
Query Example
PROG:DEF:ALL?
-> parameter list
Query Format
PROGram:EXECuted:DEFine:ALL?
Description
This query returns the parameter list for the executing program
number or name.
Parameters
Option: PROGRAM, NUMBER [,<cr>} or [,<nr1>]
Option: MEMORY [,<cr>]
Parameter list define string <cr>,<cr>,….,<cr>
Query Example
PROG:EXEC:DEF:ALL? 3
-> parameter list
Command Syntax
PROGram[:SELected]:INFOrmation <cr> [,<nr1>] [,<cr>]
Description
This command assigns program information data to the selected
program.
Parameters
Information string <cr>
Option: PROGRAM NUMBER [,<nr1>]
Option: MEMORY [,<cr>]– Available are: INTERNAL | RAM | USB
Parameter Format
<cr> [,<nr1>] [,<cr>]
Example
PROG:INFO 3, INTERNAL, SAMPLE TEST
Query Format
PROGram[:SELected]:INFOrmation? [<nr1>,] [,<cr>]
Returned Data Format
<cr>
Query Example
PROG:INFO? 2, USB
-> Program info string