AFX SERIES® OPERATION MANUAL
SECTION 13:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS)
• All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 380 of 402
Error Source
Code
Category
Error Message
Possible Cause
Resolution
Front panel
Error
99
Error
AC Voltage not allowed in
"DC mode".
Setting conflict. Setting
does not match mode
Check setting
Front panel
Error
100
Error
DC voltage set point
cannot change due to
user limit.
Setting conflict. Setting
outside of User Limits
Check setting
Front panel
Error
101
Error
AC voltage set point
cannot change due to
user limit.
Setting conflict. Setting
outside of User Limits
Check setting
Front panel
Error
102
Error
DC voltage set point
cannot change due to low
range.
Setting conflict. Setting
outside of User Limits
Check setting
Front panel
Error
103
Error
AC voltage set point
cannot change due to low
range.
Setting conflict. Setting
outside of User Limits
Check setting
Front panel
Error
104
Error
Waveform change in
progress.
Waveform change in
progress
Wait
Front panel
Error
105
Error
Error changing service
name
Internal Service Error.
Could not change service
Try recycling power. If
error persists, contact
customer service
Front panel
Error
106
Error
Error getting service
name
Internal Service Error.
Could not get service
name
Try recycling power. If
error persists, contact
customer service
Front panel
Error
107
Error
Redundant segments
were combined.
Optimization. Segment
data received contained
redundant segments
which were removed
Not needed
Front panel
Error
108
Error
Redundant steps were
combined.
Optimization. List Step
data received contained
redundant steps which
were removed
Not needed
Front panel
Error
109
Error
Transient step mode not
available on UPC
compatible mode.
Setting conflict. Step
mode only supported in
AFX mode.
Switch to AFX mode or
use Segments
Front panel
Error
110
Error
System is about to
reboot.
Warning, Reboot
imminent
Wait
Front panel
Error
111
Error
Cannot reboot system.
Soft reboot failed. Front
panel could not reboot
itself.
Try recycling power. If
error persists, contact
customer service
Front panel
Error
115
Error
Unable to renew the
DHCP lease. Changing to
Auto-IP mode.
LAN Error. IP address
lease from DHCP expired
Renew IP lease of use
Auto IP mode
Front panel
Error
116
Error
Failed starting firmware
update.
Firmware Update Error.
Unable to start firmware
update
Check for correct
firmware image file and
version.
Front panel
Error
117
Error
Unable to execute this
action with output
enable.
Setting conflict.
Requested action not
possible with output ON
Turn output OFF