AFX SERIES® OPERATION MANUAL
SECTION 13:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS)
• All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 384 of 402
Error Source
Code
Category
Error Message
Possible Cause
Resolution
Front panel
Error
181
Error
Undiscovered node
detected. Run unit
discovery to recover.
An inconsistency was
detected in the unit
internal communication
network.
Turn unit off, check
parallel cables if they
exist, and then turn unit
on. If problem recurs
contact customer service.
Front panel
Error
182
Error
Incorrect parallel unit
count
Setting conflict. Auxiliary
unit count does not
match expected count
setting
Check all parallel cables
between units. Run
parallel unit discovery
from System menu to
recover or adjust
expected count to match
actual no of units
Front panel
Error
183
Error
Invalid processor type
Auxiliary unit not
recognized
Check all parallel cables
between units. Run
parallel unit discovery
from System menu to
recover
Front panel
Error
184
Error
Daisy chain invalid type
Error during discovery
Check all parallel cables
between units. Run
parallel unit discovery
from System menu to
recover
Front panel
Error
185
Error
Undiscovered controller
node was detected.
An inconsistency was
detected in the power
source's internal
communication network.
Turn unit off, check
parallel cables if they
exist, and then turn unit
on. If problem recurs
contact customer service.
Front panel
Error
186
Error
No master front panel
was detected.
Error during discovery.
No Master found
Check all parallel cables
between units. Run
parallel unit discovery
from System menu to
recover
Front panel
Error
187
Error
More than enabled
master controller is was
detected. Going to
inactive state.
Error during discovery.
Too many masters
Check all parallel cables
between units. Run
parallel unit discovery
from System menu to
recover
Front panel
Error
188
Error
One or more units are not
energized or have a
failure.
Error during discovery.
Error with one or more
Auxiliary units found
during discovery
Check all parallel cables
between units. Make sure
all units are powered on.
Run parallel unit
discovery from System
menu to recover
Front panel
Error
189
Error
Incompatible node
detected.
Error during discovery.
Error with one or more
Auxiliary units found
during discovery
Turn unit off, check
parallel cables if they
exist, and then turn unit
on. If problem recurs
contact customer service.