AFX SERIES® OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS)
• All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 272 of 402
Query Format
SYSTem:LANGuage:CATalog?
Description
Returns list of available languages that can be selected for front panel
operation.
Returned Data Format
<cr>
Query Example
SYST:LANG?
english, chinese
Query Format
SYSTem:LXI:FEATures?
Description
R eturns string listing supported LXI features.
Returned Data Format
<cr>
Query Example
SYST:LXI:FEAT?
None
Query Format
SYSTem:LXI:VERSion?
Description
Returns LXI revision compliance version number.
Returned Data Format
<cr>
Query Example
SYST:LXI:VERSION?
LXI Core 2011
Query Format
SYSTem:MODE?
Description
Returns LOCAL (0) or REMOTE (1) front panel status. Use IEEE 488.2
command commands *LLO to lock front panel and *GTL to release
front panel operation.
Returned Data Format
<b>
Query Example
SYST:MODE?
1
Query Format
SYSTem:SERIALNUM?
Description
Returns the serial number of the power source. Same information
can be queried with the *IDN? command
Returned Data Format
<nr1>
Query Example
SYST:HWREV?
0
Query Format
SYSTem:TIME?
Description
Returns real time clock date and time.
Note: Since both date and time are returned, there is no
SYSTem:DATe?
Returned Data Format
<mm/dd/yy hh:mm:ss:mm
Query Example
SYSTem:TIME?
29/05/2018 14:40:57