AFX SERIES® OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS)
• All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 263 of 402
Command Syntax
[SOURce:]KVA:LIMit#
Description
This command sets the programmable apparent power limit level in
kVA for phase #. If # is omitted, all available phases are set to the
value specified. The max available apparent power for a phase can be
obtained using the [SOURce:]KVA:LIMit#:MAX? query command.
Parameters
Limit value in kVA
Parameter Format
<nr2>
Example
KVA:LIM 2.5
Query Format
[SOURce:]KVA:LIMit#?
Returned Data Format
<nr2>
Query Example
POW:LIM1?
2.5000
Query Format
[SOURce:]KVA:LIMit#:MAX?
Description
Returns maximum available apparent power capability for the
specified phase # in kVA. If # is omitted, returns maximum available
apparent power level for last phase selected. Typically, this value will
be the same for all phases.
Returned Data Format
<nr2>
Query Example
KVA:LIM1:MAX?
5.0000
Command Syntax
[SOURce:]KVA:PROTect:LEVel
Description
This command sets the apparent power protection trip level in kVA
for all available phases. If the apparent power of any phase exceeds
this trip level, the power source will shut off the output to protect the
load.
Parameters
True power trip limit level in kW
Parameter Format
<nr2>
Example
KVA:PROT:LEV 1.4567
Query Format
[SOURce:]KVA:PROTect:LEVel?
Returned Data Format
<nr2>
Query Example
KVA:PROT:LEV?
1.4567