AFX SERIES® OPERATION MANUAL
SECTION 7:
Rear Panel, Connectors and Protection
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS)
• All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 191 of 402
IMMEDIATE
[ ON | OFF ] Ignore phase update setting if ON
AUTORUN
[ ON | OFF ] No RUN command required if ON
7.3.13.9
Strobe Output
The Strobe Output is used to synchronize or trigger external equipment to an event
occurring on the AC power source.
Available settings are:
TRANSIENT
ON = Strobe output on transient start
OUTPUT STATE
ON = Strobe output on relay close
SOURCE
ON = Strobe output on any program parameter change
7.3.13.10
Remote Control
The remote control input is used to control operation of the output relay.
Available settings are:
DISABLED
No remote output control
REMOTE INHIBIT
Contact closure needed to close output relay
REMOTE ENABLE
Contact closure or front panel can control output relay
See Section 6.8.5.6.