46
Performance checking
SGA Signal Generator
- black/grey
10. Return the Signal Generator to ‘Continuous’ output.
11. Press the ‘M’ button on the Function Checker to select
‘Con’ (connected).
12. Plug the Direct Connection Leads (red and black) into
the socket on the Transmitter and check the Connected
Mode icon is displayed at the top of the display. Attach a
crocodile clip to each terminal on the Function Checker.
CORRECT RESULT
: The audio response should change
to a lower pitch as the second crocodile clip is attached
to the second terminal. The Function Checker bar graph
should show an indication of 5/10 full scale and the
‘33kHz’ icon should show in the top left hand corner
on the Function Checker display.
NOTE
If the CORRECT RESULT is not achieved, the cause may be a set of faulty Direct Connection Leads.
Replace with good leads and try the test again.
Function Checker
Function Checker