![background image](http://html.mh-extra.com/html/btsr/smart-200-tss/smart-200-tss_operating-manual_2825704025.webp)
Operation
SMART 200 TSS
-3.9 -
The following figure shows an example, in case of ENABLE signal programmed
as NO.
#
The sensor signals a defect
(red LED blinking) and activates the STOP output.
$
The ENABLE signal is activated while The STOP signal is still active.
%
The sensor immediately releases the STOP signal, but maintains the defect signalling
(red LED
blinking).
&
The sensor is re-enabled and, after waiting for a time corresponding to DELAY CONTROL
(green LED blinking),
it resumes the normal control
(green LED permanently lit).
Electrical Characteristics of ENABLE signal.
!"
0 - 24 VDC
To ensure a correct system operation, each TS5.. sensor must have its ENABLE
signal connected to the machine in such a way that the system can distinguish
among the following:
-
a stop due to an operator action
-
a stop due to a fault detection
-
a machine position running correctly
-
a standstill machine position
Interpretation of the signaling lights located on the sensors
Green Led ON
Sensor under normal control;
No defects detected by the sensor either in Control on
Monitor mode.
Green LED FLASHING
!"
Sensor under automatic numbering procedure.
!"
Sensor in Delay Control phase
!"
Sensor disabled via HW
(ENABLE signal)
or SW
Red LED FLASHING
During the machine operation either in Control or
Monitor mode the sensor detected a failure condition.
1 flash
TENS H
(*)
2 flashes
PEAK H
(*)
Lit
NOYARN
(yarn missing)
(*)
Green LED FLASHING
Red LED FLASHING
During the machine operation either in Control or
Monitor mode the sensor detected a failure condition.
1 flash
TENS L
(*)
2 flashes
PEAK L
(*)
Lit
NOYARN
(yarn missing)
(*)
Green LED ON
Red LED ON
Sensor locked. Switch off and on the system. If the
condition persists, replace the sensor.
Green LED OFF
Red LED OFF
Sensor not powered.
(*)
See the relevant descriptions in the fallowing pages.
Summary of Contents for SMART 200 TSS
Page 1: ...SMART 200 TSS TS5 YARN CONTROL SYSTEM Operating Manual Rev 2 0 July 2003 ENGLISH ...
Page 8: ...Introduction I 4 SMART 200 TSS Page intentionally left blank ...
Page 16: ...Technical data and installation 2 6 SMART 200 TSS Page intentionally left blank ...
Page 22: ...Operation 3 6 SMART 200 TSS Technical Characteristics of TS5 sensor Sizes mm ...
Page 32: ...Operation 3 16 SMART 200 TSS Enabling the SETUP Menu Functions CONFIG ...
Page 34: ...Operation 3 18 SMART 200 TSS Enabling the GRAPH Menu Function ...
Page 74: ...Operation 3 58 SMART 200 TSS Production Report Example ...
Page 80: ...Troubleshooting and Maintenance 4 6 SMART 200 TSS Page intentionally left blank ...
Page 82: ...Appendix A Quick Reference Symbols Key A 2 SMART 200 TSS ...
Page 83: ...Appendix A Quick Reference Symbols Key SMART 200 TSS A 3 ...
Page 84: ...Appendix A Quick Reference Symbols Key A 4 SMART 200 TSS ...
Page 85: ...Appendix A Quick Reference Symbols Key SMART 200 TSS A 5 ...
Page 86: ...Appendix A Quick Reference Symbols Key A 6 SMART 200 TSS ...
Page 87: ...Appendix A Quick Reference Symbols Key SMART 200 TSS A 7 ...
Page 88: ...Appendix A Quick Reference Symbols Key A 8 SMART 200 TSS ...
Page 89: ...Appendix A Quick Reference Symbols Key SMART 200 TSS A 9 ...
Page 90: ...Appendix A Quick Reference Symbols Key A 10 SMART 200 TSS ...
Page 91: ...Appendix A Quick Reference SMART 200 TSS A 11 Note ...
Page 92: ...Appendix A Quick Reference A 12 SMART 200 TSS Page intentionally left blank ...