Operation
SMART 200 TSS
-3.35 -
SENSOR TEST - Sensors Test
SETUP
#
#
#
#
CONFIG
#
#
#
#
TEST
#
SENSOR
This function gives you the possibility to check communications between the
SMART 200 TSS terminal and (one by one) each of the connected sensors.
In this way it is possible to check that:
!"
All sensors are correctly numbered and identified
!"
All sensors respond correctly to the terminal
!"
The same number has not been assigned to more that 1 sensor.
This function is particularly useful during the testing phase (immediately after
installation) and when operation problems occur which require a check of each
sensor individually.
The test does not send any diagnostic message to the SMART system display!
The operator shall simply select the number of the desired sensor (DEV XXX) by
using the button NEXT CY and checking that the red LED of the selected sensor is
flashing.
Press
until the TEST CONFIG option is displayed.
Press
to have access to the Test function.
This screen indicates that the sensor test is going to start.
Press
to continue.
DEV XXX
(or A XXX if the SIDE option is enabled)
indicates the sensor which is
being tested
(initially sensor no. 1).
Check that the Red LED of sensor XXX is
flashing and there are no other sensors with the Red LED FLASHING
!
If the Red LED of the sensor that should respond to the number XXX is not
flashing, it means that the sensor is faulty or that the sensors numbering
procedure has not been performed correctly. In this case try to renumber the
sensors (refer to “Parameters setting for initial installation") and, if required,
replace the sensor.
!
If the Red LED is flashing on more than one sensor, it means that the same
number has been assigned to more than one sensor. In this case it will be
necessary to repeat the sensor numbering procedure (refer to “Parameters
setting for initial installation”).
Press
to select the next sensor and check that the Red LED of the selected
sensor is flashing.
Repeat this test on all connected sensors.
Press
to switch from Side A to Side B and vice versa.
Press once
to return to the CONFIG Menu, or twice to return to the Main
Menu.
A
14
Summary of Contents for SMART 200 TSS
Page 1: ...SMART 200 TSS TS5 YARN CONTROL SYSTEM Operating Manual Rev 2 0 July 2003 ENGLISH ...
Page 8: ...Introduction I 4 SMART 200 TSS Page intentionally left blank ...
Page 16: ...Technical data and installation 2 6 SMART 200 TSS Page intentionally left blank ...
Page 22: ...Operation 3 6 SMART 200 TSS Technical Characteristics of TS5 sensor Sizes mm ...
Page 32: ...Operation 3 16 SMART 200 TSS Enabling the SETUP Menu Functions CONFIG ...
Page 34: ...Operation 3 18 SMART 200 TSS Enabling the GRAPH Menu Function ...
Page 74: ...Operation 3 58 SMART 200 TSS Production Report Example ...
Page 80: ...Troubleshooting and Maintenance 4 6 SMART 200 TSS Page intentionally left blank ...
Page 82: ...Appendix A Quick Reference Symbols Key A 2 SMART 200 TSS ...
Page 83: ...Appendix A Quick Reference Symbols Key SMART 200 TSS A 3 ...
Page 84: ...Appendix A Quick Reference Symbols Key A 4 SMART 200 TSS ...
Page 85: ...Appendix A Quick Reference Symbols Key SMART 200 TSS A 5 ...
Page 86: ...Appendix A Quick Reference Symbols Key A 6 SMART 200 TSS ...
Page 87: ...Appendix A Quick Reference Symbols Key SMART 200 TSS A 7 ...
Page 88: ...Appendix A Quick Reference Symbols Key A 8 SMART 200 TSS ...
Page 89: ...Appendix A Quick Reference Symbols Key SMART 200 TSS A 9 ...
Page 90: ...Appendix A Quick Reference Symbols Key A 10 SMART 200 TSS ...
Page 91: ...Appendix A Quick Reference SMART 200 TSS A 11 Note ...
Page 92: ...Appendix A Quick Reference A 12 SMART 200 TSS Page intentionally left blank ...