Technical data and installation
SMART 200 TSS
- 2.5 -
Connection Cables and Power Supply Devices
To correctly install the
SMART 200 TSS
system and sensors, it is necessary to use
a certain number of connecting cables provided by
BTSR;
their length and type
depend on the specific requirements and application types.
The following table lists at glance the types and lengths of the main connection
cables, which
BTSR
may provide. For further details and queries about the cables
and accessories available, please contact your local
BTSR
dealer.
SMART Power Cables (I/O Connectors)
FE10/200
Length 200 cm
FE10/500
Length 500 cm
Cables 4 x 0.35 mm with Female to Female Connector for connections
between SMART 200 TSS /PSU 10A and MA2FE8 Doubler Cable
FE100/FEC
Length 100 cm
FE200/FEC
Length 200 cm
FE300/FEC
Length 300 cm
FE400/FEC
Length 400 cm
Doubler Cable from one Male to two Female with Independent Stop
and Ground outputs to Connect a Solenoid-valve, Cutter, Alarm
Signalling Light, etc.
MA2FE8
Extension Cable 4x0.35 mm with Male and Female connector.
MA50/FEC
Length 50 cm
MA100/FEC
Length 100 cm
MA200/FEC
Length 200 cm
Transformers for SMART 200 TSS
TRF1524/100
Output 15/24 Vac 100VA
(can be used with up to 40 sensors)
TRF24/300VA
Output 24 Vac/300VA
(can be used with more than 40 sensors)
Stabilised Power Supply with 24 Vdc output, 10A Peak, 6A
continuous
PSU 10A
Required with more than 40 sensors (up to a maximum of 100
sensors for each PSU 10A)
Printer for SMART 200 TSS
PRNT 01
Printer with clock-calendar feature for production report, including
CV485/232
conversion interface cable.
Summary of Contents for SMART 200 TSS
Page 1: ...SMART 200 TSS TS5 YARN CONTROL SYSTEM Operating Manual Rev 2 0 July 2003 ENGLISH ...
Page 8: ...Introduction I 4 SMART 200 TSS Page intentionally left blank ...
Page 16: ...Technical data and installation 2 6 SMART 200 TSS Page intentionally left blank ...
Page 22: ...Operation 3 6 SMART 200 TSS Technical Characteristics of TS5 sensor Sizes mm ...
Page 32: ...Operation 3 16 SMART 200 TSS Enabling the SETUP Menu Functions CONFIG ...
Page 34: ...Operation 3 18 SMART 200 TSS Enabling the GRAPH Menu Function ...
Page 74: ...Operation 3 58 SMART 200 TSS Production Report Example ...
Page 80: ...Troubleshooting and Maintenance 4 6 SMART 200 TSS Page intentionally left blank ...
Page 82: ...Appendix A Quick Reference Symbols Key A 2 SMART 200 TSS ...
Page 83: ...Appendix A Quick Reference Symbols Key SMART 200 TSS A 3 ...
Page 84: ...Appendix A Quick Reference Symbols Key A 4 SMART 200 TSS ...
Page 85: ...Appendix A Quick Reference Symbols Key SMART 200 TSS A 5 ...
Page 86: ...Appendix A Quick Reference Symbols Key A 6 SMART 200 TSS ...
Page 87: ...Appendix A Quick Reference Symbols Key SMART 200 TSS A 7 ...
Page 88: ...Appendix A Quick Reference Symbols Key A 8 SMART 200 TSS ...
Page 89: ...Appendix A Quick Reference Symbols Key SMART 200 TSS A 9 ...
Page 90: ...Appendix A Quick Reference Symbols Key A 10 SMART 200 TSS ...
Page 91: ...Appendix A Quick Reference SMART 200 TSS A 11 Note ...
Page 92: ...Appendix A Quick Reference A 12 SMART 200 TSS Page intentionally left blank ...