Planned Maintenance Procedures
48
Service Manual
1997-10-21
2.5. Electrical Connections
All electrical connections should be checked that they are
clean and tight. Plug-in connectors should be unplugged and
plugged back in to clean the terminals. If the truck is equipped
with any of the cold-storage, freezer use, or corrosive
environment application packages, the di-electric compound
in the plug-in connectors should be renewed. This compound
is available through the parts department of your authorized
dealer.
2.6. Contactor Tips (NOT Sealed)
Inspect contactor tips for arcing, pitting, or burning. Minor
pitting of the tips is not a problem. However, if the tips are
pitted through the tip to the copper bar, the tips should be
replaced. DO NOT file tips. Replace tips only in complete
sets. Some contactors have concealed tips or are fully sealed
so that tips cannot be replaced.
2.7. Motor Brushe
Minimum brush lengths are given in the specifications section
of this manual. As a rule of thumb, the brushes should be
replaced if the brush spring is within 1/16 in. of touching the
brush holder.
2.8. Drive Motor
Blow out the drive motor fan and vents. Check for any signs
of oil on the drive motor fan and air vents. Check for any
damage to the fan or air vents.
Compressed air used for cleaning MUST
be reduced to less than 30 psi., and then
only with effective chip-guarding and
personal protective equipment worn.
WARNING