EV100 Handset Operation
234
Service Manual
1997-09-15
6.4. Function 4
Current Limit (Push 4)
This function allows for the adjustment of the current limit of
the control. The rating of the control will determine the range
of adjustment for this function. Please refer to the operating
instructions for the control used in this truck.
Range
See control C/L curves
Set
0 to 255
Example:
0 = minimum current
255 = maximum current
6.5. Function 5
Plugging Distance (Current) (Push 5)
This function allows for the adjustment of the plugging
distance of the truck. The larger the current setting, the
shorter the stopping distance.
Range
200 to 1000 amps
Set
0 to 255
Resolution 3.14 amps per set unit
Example:
Setting of 20 = 1263 amps
6.6. Function 6
1A Drop Out Current (Push 6)
This function allows for the adjustment of the 1A contactor
drop out current. The 1A contactor will be dropped out and
the vehicle motor torque will be limited to SCR current limit
when the set drop out current is reached.
Range
450 to 1260 amps
Set
0 to 250
Resolution 3.24 amps per set unit
Settings above 250 set units will disable 1A drop out function
(1A will not drop out).
Example:
Setting of 20 = 515 amps
Plug settings must be in accordance with
control
operating instructions.
An
excessively high
setting could cause
damage to control system or drive motor.