EV100 Handset Operation
PS
S5.5
5710
F-code
Section
C-code
Version no
T-code
000
© BT Products AB
237
Service Manual
1997-09-15
6.11. Function 15
Battery Volts (Push 15)
This function allows for the adjustment of voltage range for
controls equipped with the Battery Discharge Indication
function. In order for the BDI to operate properly, the setting
as shown in the table must be entered.
The following functions have function numbers larger than the
numbers on the Handset
keyboard. To access these
functions, push the CONT key and the number shown in the
following instructions at the same time.
6.12. Function 16
Pedal Position Plug (Push CONT and 1)
This function will allow the adjustment of the pedal position
plug range. Pedal position will reduce the plugging current to
the current value set by this function as the accelerator is
returned to the creep speed position. Maximum plug current
is obtained with the accelerator in the top speed position.
Range
100 to 930 amps
Set
0 to 255
Resolution 3.2 amps per set unit
Example
Setting of 20 = 164 amps
To disable the pedal position plug function, adjust the current
value to the same current value as the plug distance current.
Example: If plug distance current Function 5 is set at 500
amps, then set pedal plug current at 500 amps. With this
setting pedal position will have no effect on plugging distance.