C-code
EV100 LX Control Status Codes
174
Service Manual
1997-10-22
STATUS CODE
-48
DESCRIPTION
MEMOR
RECALL
No
Look ahead test for T2 volts (less than 12% battery
volts).
CIRCUIT
Traction
SYMPTOM
Forward or reverse contactor will not pick up.
POSSIBLE CAUSE
Defective forward or reverse contactor
* Check for welded forward or reverse contactor power tips
* Check for sluggish operation of forward or reverse
contactor.
Defective 3REC circuit
* Check for shorted 3REC
* Check for shorted 3REC snubber (23REC).
Figure 1.
STATUS INDICATION CRITERIA
This status code is displayed when the voltage at
T2 is less than 12 % of battery volts.
STATUS CODE
-49
DESCRIPTION
MEMOR
RECALL
Yes
5REC does not turn on properly.
CIRCUIT
Traction
SYMPTOM
Forward or reverse contactor will open and close, then open and
then can only be closed by opening the key switch.
POSSIBLE CAUSE
Defective 5REC circuit
* Check for shorted 5REC
* Check for shorted 5REC snubber (25REC)
* Check that 5REC will gate on
* Check for open circuit or loose connection between 5REC
gate and PZ12 (white/violet wire).
Shorted 2REC circuit
* Check for 2REC and 2REC snubber (22REC) for short
circuit.
Defective capacitor circuit
* Check for open capacitor
* Check for loose connections at capacitor terminals.
Figure 1.
STATUS INDICATION CRITERIA
This status code is displayed when 5REC circuit
fails to turn on.
F
F
R
R
T2
S2
S1
Field
A2
A2
A1
NEG.
3REC
23 Filter
SCR
Current
Sensor
PZ12
PZ14
5REC
25REC
T4
T3
T4
T3
2REC
Reactor
2REC
Orange
Wire
T5
White/Violet
Choke
T5
Orange
Wire
White/Violet
X1
Reactor
Return
Summary of Contents for OE35
Page 2: ...Return ...
Page 10: ... BT Products 8 Table of Contents Return ...
Page 331: ...Return ...