EV100 LX Control Status Codes
164
Service Manual
1997-10-22
STATUS CODE
-04
DESCRIPTION
MEMOR
RECALL
Yes
Switch input low after initial start up.
CIRCUIT
Traction
SYMPTOM
Forward or reverse contactor will not pick-up.
POSSIBLE CAUSE
Forward or reverse directional switch closed on initial start up.
* Close key and foot switch. Status code will change to 03 if
reverse directional switch or to 02 if forward directional
switch is closed. If either of these codes appear, return
directional switch to neutral and then select the desired
direction.
Excessive leakage from TB2 to battery negative.
* Check voltage at TB2 with key and foot switches closed
and directional switch in neutral. Voltage should be greater
than 60% of battery voltage.
* If less than 60% battery voltage; disconnect battery and
remove wire and measure resistance from wire to SCR
negative. Value should be less than 22K ohms.
Figure 1.
STATUS INDICATION CRITERIA
This status code is displayed when TB2 voltage is
less than 60% of battery volts at initial start-up
(foot switch closure).
STATUS CODE
-05
DESCRIPTION
MEMOR
RECALL
No
Brake switch fails to close.
CIRCUIT
Traction
SYMPTOM
Forward or reverse contactor will not pick up.
POSSIBLE CAUSE
Defective brake switch circuit.
* Check brake switch to insure closure when foot pedal is
depressed.
* Check for open circuit or loose connections in wiring from
foot switch to brake switch and from TB2 to brake switch.
Figure 1.
STATUS INDICATION CRITERIA
This status code is when TB1 is less than 2.5 volts
and TB2 is less than 60% battery volts.
Key Switch
Gate Switches
Foot Sw.
EM. DISC.
TB4
TB3
TB2
TB5
Forward Switch
Brake Switch
Chain Switch
Key Switch
Foot SW.
Gate Switches
Chain Switch
Brake Switch
NEG.
ACCEL. POT.
EM. DISC.
TB3
TB4
TB2