EV100 LX Control Status Codes
PS
S5.7
5410
F-code
Section
C-code
Version no
T-code
000
OE35
© BT Products
175
Service Manual
1997-10-22
STATUS CODE
-50
DESCRIPTION
MEMOR
RECALL
No
Capacitor volts low
CIRCUIT
Traction
SYMPTOM
Forward or reverse contactor picks up. Control does not operate.
POSSIBLE CAUSE
Defective 2REC circuit
* Open circuit or loose connection between spider assembly
and 5REC (BUS A).
* Open circuit or loose connection between 5REC and
2REC.
* Open circuit or loose connection between 2REC and PZ11
(red wire) and between 2REC gate and PZ10 (white/red
wire).
* Check 2REC to insure that it will gate on.
Figure 1.
STATUS INDICATION CRITERIA
This status code is displayed when 2REC circuit
fails to turn on at initial start up.
STATUS CODE
-51
DESCRIPTION
MEMOR
RECALL
Yes
Excessive capacitor voltage when motor current is high.
CIRCUIT
Traction
SYMPTOM
Forward or reverse contactors open and close, then can only be
closed by opening and closing the key switch.
POSSIBLE CAUSE
Excessive source inductance
* Tag lines without filters are being used.
* Battery cables are too long.
High peak current in motor
* Check for shorted field winding.
* Check for shorted armature winding.
Figure 1.
STATUS INDICATION CRITERIA
This status code is displayed when capacitor volts
exceed 225 volts and motor current is greater than
300 amps.
Bus A
Bus B
5REC
Spider
Red Wire
White/Red
2REC
PZ10
White/Red
T5
X1
2REC
Wire
F
F
A1
A2
A2
SCR
Current
Sensor
NEG.
Field
S1
S2
R
R
T2
Return