Battery Controller / Hourmeter / Lift Interrupt
152
Service Manual
1997-04-15
3.2. Reset
The instrument is supplied with a fixed reset voltage setting.
This factory-set reset voltage brings the BC to full regardless
of its previous level. The reset will be done when the battery
has been charged and connected to the machine.
3.3. Key Switch
The electronics of the BC and the LCD of the hourmeter are
energized as long as the machine battery remains connected
to the gauge. The display of the BC is turned on and off by
the key switch.
12 Volt and 300 AMP Controllers
The key switch also enables timing function of the hourmeter.
With the key switch ON, the hourmeter can be activated by
the connection number 6 at the rear of the BC. With the key
switch OFF, the hourmeter will not respond to the connection
number 6, and the LCD of the hourmeter will be off.
400 AMP Controllers
The drive transistor controller enables the timing function of
the hourmeter, whenever there is current going to the drive
motor. Also, the timing function is enabled whenever S52
raise switch is closed.
NOTE! The discharge adjustments can be made at any
time during a working cycle before lift lockout.
However, discharge potentiometer adjustments
made late in a working cycle have little or no
effect in delaying the lift lockout in that particular
working cycle. Normally discharge potentiometer.
Adjustments are made before or at the beginning
of a working cycle to effectively change the
discharged profile of that working cycle. Once lift
lockout does occur, the gauge must be reset
before discharge potentiometer. adjustments can
have an effect.