PS
S5.7
5410
000
OE35
Version no
T-code
F-code
Section
C-code
EV100 LX Control Status Codes
172
Service Manual
1997-10-22
STATUS CODE
-44
DESCRIPTION
MEMOR
RECALL
Yes
1REC did not turn off properly.
CIRCUIT
Traction
SYMPTOM
Forward or reverse contactors open and close, then can only be
closed by opening and closing the key switch.
POSSIBLE CAUSE
Defective 5REC circuit
* Check for shorted 5REC.
* Check for shorted 5REC snubber (25REC).
Defective 2REC circuit.
* Check for shorted 2REC.
* Check for shorted 2REC snubber (22REC).
Open choke (1X).
* Check for open circuit between T5 and T3. Ohm meter
should read zero ohms.
1REC defective.
* Turn off time for 1REC out of specification. No field test is
possible. Replace 1REC after above checks, show no
problem found.
Figure 1.
STATUS INDICATION CRITERIA
This status code is displayed when, during SCR
operation, 1REC fails to turn off.
STATUS CODE
-45
DESCRIPTION
MEMOR
RECALL
Yes
1REC did not turn on properly.
CIRCUIT
Traction
SYMPTOM
Forward or reverse contactor will open and close, then open and
then can only be closed by opening and closing the key switch.
POSSIBLE CAUSE
Defective 2REC circuit
* Check for shorted 2REC.
* Check for shorted 2REC snubber (22REC).
Defective 1REC circuit
* Check for open circuit or loose connections between 1REC
and PZ8 (white/blue wire).
* Check for open circuit or loose connections between 1REC
(3REC snubber) and PZ9 (blue wire).
Defective 1REC
* Intermittent or open 1REC gate. Field test may or may not
show defect. Replace 1REC after above checks, show no
problem found.
Figure 1.
STATUS INDICATION CRITERIA
This status code is displayed when 1REC fails to
gate on.
P
25REC
T4
T3
X1
Choke
T5
22REC
5REC
2REC
1REC
P
1REC
Blue
White/Blue
PZ8
PZ9
2REC
22REC
Return
Summary of Contents for OE35
Page 2: ...Return ...
Page 10: ... BT Products 8 Table of Contents Return ...
Page 331: ...Return ...