EV100 LX Control Status Codes
PS
S5.7
5410
F-code
Section
C-code
Version no
T-code
000
OE35
© BT Products
177
Service Manual
1997-10-22
STATUS CODE
-54
DESCRIPTION
MEMOR
RECALL
Yes
Shorted F, R or 1A contactor coil driver.
CIRCUIT
Traction
SYMPTOM
Control will not operate
POSSIBLE CAUSE
Defective logic card
* Replace logic card
Figure 1.
STATUS INDICATION CRITERIA
This status code is displayed when either the
forward, reverse or 1A contactor coil driver is
shorted internal to the logic card.
STATUS CODE
-57
DESCRIPTION
MEMOR
RECALL
Yes
Current sensor output voltage polarity check
CIRCUIT
Traction
SYMPTOM
Forward or reverse contactors open and close, then can only be
closed by opening and closing the key switch.
POSSIBLE CAUSE
Reversed yellow and green current sensor wires
* Insure that the green wire connects to PZ4 with no open
circuits and the yellow wire connects to PZ3 with no open
circuits or loose connections.
Reversed power cable connection
* Insure that the battery negative cable connects to SCR
NEG and the motor A2 cable connects to SCR A2.
Figure 1.
STATUS INDICATION CRITERIA
This status code is displayed when the voltage
input to PZ4 and PZ3 is the wrong polarity.
SCR
Current
Sensor
A1
A2
A2
NEG.
PZ3
PZ4
Green
Yellow
Return
Summary of Contents for OE35