Electrical System Troubleshooting Charts
PS
S5.4
5460
F-code
Section
C-code
Version no
T-code
001
OE35
211
Service Manual
1996-10-15
© BT Products
negative.
1.4.3 No lift, travel okay; lift pump (LP) contactor closes.
Conditions for test: Battery connected, key switch
in “on” position, start button pushed and released,
emergency disconnect closed. Foot, raise and gate
switches closed. Lift pump contactor closed.
Test for battery volts at:
1. Positive side of contactor bus bar.
0 volts - repair open cable #5 from fuse 1, 400
AMP>
2. Pump motor side of contactor bus bar.
0 volts - repair contactor, replace tips.
3. A1 terminal on lift pump motor.
0 volts - repair open cable 20 from LP
contactor.
4. S2 terminal on motor.
0 volts - repair motor.
Battery volts - repair open cable 13 to battery
negative.
1.5
Lowering
1.5.1 No low speed lowering, low and high speed raise
okay.
Conditions for test: Battery plugged in, key switch
in “on” position, start button pushed and engaged,
emergency disconnect contactor closed, foot pedal
switch closed, gate switches closed, platform
raised above 24 inches, slow speed lowering
switch activated.
Test for battery voltage at:
Return