Electrical systems – 5000 LPE 240
Diagnostic and troubleshooting
Order number
Date
Valid from serial number
T-code
225553-040
2005-05-11
723984-
660, 661, 662, 497
© BT Europe AB
Service Guide
LWE180, LWE200, LPE200, LPE240
10- 47
10.9 Diagnostic and troubleshooting
10.9.1 Error codes and troubleshooting
The table below depicts the error codes that may be shown by the STA-
TUS LED or read using the handheld terminal.
STATUS LED
Handheld ter-
minal display
Explanation
Possible cause
LED off
-
No voltage or
defective regulator
Burnt fuse, bad contact, not con-
nected, defective regulator
LED on
-
Defective regulator
Defective regulator
1,1
¤ ¤
CURRENT
SHUNT FAULT
Built-in current
shunt defective
Armature current sensor fault in motor
controller.
1,2
¤ ¤¤
HW FAILSAFE
Power amplifier
CAN-timeout
Motor controller reports unexpected
loss of data flow from tiller head
1,3
¤ ¤¤¤
M- SHORTED
Internal M- short to
B-
Problem with switch transistor in arma-
ture circuit inside motor controller
3,1
¤¤¤ ¤
CONT COIL/FLD
SHORT
Too high current for
contactor feeding
or shorted field
winding
Attempt to drive more current than
specified from outputs.
Problem to regulate field currrent.
Internal controller fault.
3,3
¤¤¤ ¤¤¤
FIELD OPEN
Open field winding
Shuntfield open, harness broken,
motor controller defect.
4,1
¤¤¤¤ ¤
LOW BATTERY
VOLTAGE
Low battery voltage
1. Battery voltage <17 volts
2. Corroded battery terminals
3. Loose battery or regulator connec-
tions
4,2
¤¤¤¤ ¤¤
OVERVOLTAGE
Overvoltage
1. Battery voltage > 33 volts
4,3
¤¤¤¤ ¤¤¤
THERMAL
CUTBACK
Over-/under-tem-
perature reduction
1. Temp. >85
o
C or < - 25
o
C
2. Truck overloaded
3. Wrong installation of transistor
regulator
4. Operation under extreme conditions
MODEL
STATUS
SERIAL
VOLTAGE
CURRENT