Electrical System – 5000 LWE 180/200 LPE 200
Error codes
Order number
Date
Valid from serial number
T-code
225553-040
2005-05-11
723984-
660, 661, 662, 497
© BT Europe AB
Service Guide
LWE180, LWE200, LPE200, LPE240
9- 25
Code
E107
Description
Contactor K10 does not close.
Possible error
cause
Problem with main contactor points or coil.
Contactor’s operating cabling off/not connected.
Interruption in the travel regulator’s output, A1/4.
Action
1.
Check if the contactor is activated.
2.
If the contactor is working, check the contact
points and accompanying cabling.
3.
If the contactor is not working, check the coil
and accompanying cabling. Measure Ohms
for the coil. Value 25-30 ohm.
4.
Check the travel regulator’s output, A1/4.