Preventive maintenance – P2 LPE 240
Maintenance schedule
Order number
Date
Valid from serial number
T-code
225553-040
2005-05-11
723984-
660, 661, 662, 497
© BT Europe AB
Service Guide
LWE180, LWE200, LPE200, LPE240
5- 3
5000.
Electrical functions
5000.1
Check the operation of the brake microswitch
in the upper and lower brake positions. Lubri-
cate the switch head
I
I/L
5000.2
Check the function of the safety switch
against collision
I
5000.3
Check the operation of the gate switch
I
I
5000.4
Check the operation of the platform switch
I
I
5000.5
Check the horn
I
I
5000.6
Check for wear to the cables
I
5000.7
Check the operation of the driver's controls
I
I
5000.8
Check the error code log and operatingtimes
I
I
5110.
Battery
5110.1
Check electrolyte levels, 10-15 mm above
the cell plates
M
5110.2
Check connections on the battery,
truck and charger
I
5110.3
Check that the cell and pole guards are
undamaged
I
5110.4
Check the fluid density and temperature
M
5110.5
Remove overflow fluid from the battery trough
C
5110.6
Check the battery lock
I
5400
Power system
5400.1
Clean and check the mountings
C/T
1
C/T
5400.2
Tighten the cable connections
T
1
5400.3
Check the contactor points on K10 and K30
I
5400.4
Check the contactor movement
I
I: Inspect, correct and replace if necessary. T: Tighten C: Clean L: Lubricate
M: Measure, correct if necessary
Pos.
no.
Work to carry out
Interval in hours - may vary due to ap-
plication
5
20
80
500
1000
3000
Interval in days/weeks/months - may
vary due to application
1d
1w
1m
6m
12m
36m