9- 24
Service Guide
LWE180, LWE200, LPE200, LPE240
© BT Europe AB
Electrical System – 5000 LWE 180/200 LPE 200
Error codes
T-code
Valid from serial number
Date
Order number
660, 661, 662, 497
723984-
2005-05-11
225553-040
Code
E106
Description
Digital outputs short-circuited or exceeding field
current limit.
Possible error
cause
Problem regulating the field current.
Internal monitoring error.
Action
1.
Check the output for main contactor K10 (A1/
4), check cabling and contacts and measure
ohms for the coil. Value 25-30 ohm. Check the
output for the brake coil K10 (A1/3), check ca-
bling and contacts and measure ohms for the
coil. Value 13-15 ohm.
2.
Check the output for horn (A1/7), check ca-
bling and contacts.
3.
Check the drive motor’s shunt winding and ca-
bling and contacts. Unfortunately it is not pos-
sible to measure ohms for the field winding us-
ing a standard universal instrument, since the
winding has a value as low as 0.3 ohm.